Vulnerabilidades em siemens
1.635 resultadosCVE-2020-15786CRITICALA vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI ComEPSS 1.5%CVE-2021-31882MEDIUMA vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions EPSS 1.5%CVE-2021-46151—A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application EPSS 1.5%CVE-2021-46153—A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application EPSS 1.5%CVE-2019-13926—A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCAEPSS 1.5%CVE-2020-7591—A vulnerability has been identified in SIPORT MP (All versions < 3.2.1). Vulnerable versions of the device could allow an authenticated attaEPSS 1.5%CVE-2021-31884—A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (EPSS 1.5%CVE-2021-27398—A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validEPSS 1.5%CVE-2021-27396—A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validEPSS 1.5%CVE-2017-12734—A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the iEPSS 1.4%CVE-2021-27380—A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). AffectedEPSS 1.4%CVE-2021-25678—A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid EEPSS 1.4%CVE-2022-36324HIGHAffected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypaEPSS 1.4%CVE-2022-26314—A vulnerability has been identified in Mendix Forgot Password Appstore module (All versions >= V3.3.0 < V3.5.1), Mendix Forgot Password AppsEPSS 1.4%CVE-2019-13925—A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCAEPSS 1.4%CVE-2019-13946HIGHProfinet-IO (PNIO) stack versions prior V06.00 do not properly limit
internal resource allocation when multiple legitimate diagnostic packagEPSS 1.4%CVE-2021-31344MEDIUMA vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions EPSS 1.4%CVE-2024-27944HIGHA vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmEPSS 1.4%CVE-2019-6568HIGHThe webserver of the affected devices contains a vulnerability that may lead to
a denial of service condition. An attacker may cause a deniEPSS 1.4%CVE-2019-10923HIGHAn attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IREPSS 1.4%