Vulnerabilities in siemens

1,679 results
Vexday analysis

Siemens apresenta footprint reduzido com apenas 2 CVEs na base, nenhuma sob ataque ativo confirmado. Uma vulnerabilidade foi publicada nos últimos 90 dias, identificada como validação inadequada de entrada (CWE-20), o que sugere risco moderado em cenários de interação com dados não confiáveis, mas sem indicadores de exploração em massa no momento.

CVE-2023-42796HIGHA vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11), CP-8050 MASTER MODULE (All versions < CPCI85 V0EPSS 0.7%CVE-2022-45936HIGHA vulnerability has been identified in Mendix Email Connector (All versions < V2.0.0). Affected versions of the module improperly handle accEPSS 0.7%CVE-2020-27003A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected appliEPSS 0.7%CVE-2022-43767HIGHA vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-EPSS 0.7%CVE-2022-34661MEDIUMA vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.15), Teamcenter V13.0 (All versions < V13.0.0.10), TeamcenteEPSS 0.7%CVE-2022-47374HIGHA vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400EPSS 0.7%CVE-2022-46143MEDIUMAffected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer EPSS 0.7%CVE-2020-15791MEDIUMA vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-4EPSS 0.7%CVE-2022-45044MEDIUMA vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.50), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 EPSS 0.7%CVE-2023-29106MEDIUMA vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versiEPSS 0.7%CVE-2022-47375HIGHA vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400EPSS 0.7%CVE-2019-13939HIGHA vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3),EPSS 0.7%CVE-2020-28394A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected appliEPSS 0.7%CVE-2020-27008A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected appliEPSS 0.7%CVE-2023-29104MEDIUMA vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versiEPSS 0.7%CVE-2022-46664HIGHA vulnerability has been identified in Mendix Workflow Commons (All versions < V2.4.0), Mendix Workflow Commons V2.1 (All versions < V2.1.4)EPSS 0.7%CVE-2020-27005A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected appliEPSS 0.7%CVE-2022-32261MEDIUMA vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a misconfiguratEPSS 0.7%CVE-2024-32740CRITICALA vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains undocumented users and credentialEPSS 0.7%CVE-2025-32852HIGHA vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injEPSS 0.7%