Linksys Routers apply.cgi Remote Command Injection
36Vexday Risk Score
Corrige pronto. Ella tiene exploit funcional público.
ssvc Attendcvss 8.6epss 3.0%
de la publicación al arma0 días
Publicada en NVD1 ago
metasploit11 feb
probabilidad de explotación
3.0%top 13% de las CVE
explotación observada
noninguna fuente lo reporta
An authenticated OS command injection vulnerability exists in various Linksys router models (tested on WRT160Nv2) running firmware version v2.0.03 via the apply.cgi endpoint. The web interface fails to properly sanitize user-supplied input passed to the ping_size parameter during diagnostic operations. An attacker with valid credentials can inject arbitrary shell commands, enabling remote code execution.
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Productos afectados
Linksys · WRT160nv2Referencias
https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/exploits/linux/http/linksys_wrt160nv2_apply_exec.rbhttps://web.archive.org/web/20140830181242/http://www.s3cur1ty.de/m1adv2013-012https://www.exploit-db.com/exploits/24478https://www.exploit-db.com/exploits/25608https://www.vulncheck.com/advisories/linksys-legacy-routers-remote-command-injection