CVE-2017-16291highCWE-121

CVE-2017-16291: fallo de gravedad alta en Insteon Hub

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 8.5epss 0.7%
Multiple exploitable buffer overflow vulnerabilities exist in the PubNub message handler for the "cc" channel of Insteon Hub running firmware version 1012. Specially crafted commands sent through the PubNub service can cause a stack-based buffer overflow overwriting arbitrary data. An attacker should send an authenticated HTTP request to trigger this vulnerability. In cmd s_sun, at 0x9d019854, the value for the `sunset` key is copied using `strcpy` to the buffer at `$sp+0x334`.This buffer is 100 bytes large, sending anything longer will cause a buffer overflow.
CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Productos afectados
Insteon · Hub