CVE-2017-6030: fallo de gravedad media en Schneider Electric Modicon M221
Schneider Electric Modicon PLCs Predictable Value Range from Previous Values
Publicada el · Actualizada el
Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.
13Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackcvss 6.5epss 2.2%
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Productos afectados
Schneider Electric · Modicon M221Schneider Electric · Modicon M241Schneider Electric · Modicon M251CVEs relacionadas — Schneider Electric Modicon M221
En el mismo producto, de las más peligrosas a las menos.