Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.
Productos afectados
ICS-CERT · Delta Industrial Automation COMMGR and accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1)PoCs públicas encontradas — 4
cve_referencewww.exploit-db.com/exploits/44965/no verificadocve_referencewww.exploit-db.com/exploits/45574/no verificadoexploitdbwww.exploit-db.com/exploits/44965no verificadoexploitdbwww.exploit-db.com/exploits/45574no verificado⚠ Recursos públicos, para evaluar la exposición de sistemas que controlas o estás autorizado a probar. Prueba solo con autorización.