CVE-2019-10920: fallo en Siemens LOGO! 8 BM (incl. SIPLUS variants)
Publicada el · Actualizada el
Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.
3Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackepss 1.5%
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Productos afectados
Siemens · LOGO! 8 BM (incl. SIPLUS variants)CVEs relacionadas — Siemens LOGO! 8 BM (incl. SIPLUS variants)