CVE-2019-13924
CVE-2019-13924
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Productos afectados
Siemens · SCALANCE S602Siemens · SCALANCE S612Siemens · SCALANCE S623Siemens · SCALANCE S627-2MSiemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)Siemens · SCALANCE X-200RNA switch familySiemens · SCALANCE X-200 switch family (incl. SIPLUS NET variants)Siemens · SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)¿Quieres saber si tu infraestructura está expuesta a esto?
Hablar con TrueHacking →