CVE-2019-18342
CVE-2019-18342
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server
(CCS) does not properly limit its capabilities to the specified purpose.
In conjunction with CVE-2019-18341, an unauthenticated remote attacker with
network access to the CCS server could exploit this vulnerability
to read or delete arbitrary files, or access other resources on the same
server.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:F/RL:U/RC:C