CVE-2020-10276: fallo crítico en Mobile Industrial Robots A/S MiR100
RVD#2558: Default credentials on SICK PLC allows disabling safety features
Publicada el · Actualizada el
Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.
28Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackcvss 9.8epss 1.5%
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Productos afectados
Mobile Industrial Robots A/S · MiR100CVEs relacionadas — Mobile Industrial Robots A/S MiR100
En el mismo producto, de las más peligrosas a las menos.
CVE-2020-10272CRITICALRVD#2554: MiR ROS computational graph presents no authentication mechanismsEPSS 2.5%CVE-2020-10271CRITICALRVD#2555: MiR ROS computational graph is exposed to all network interfaces, including poorly secured wireless networks and open wired onesEPSS 1.8%CVE-2020-10270CRITICALRVD#2557: Hardcoded Credentials on MiRX00 Control DashboardEPSS 1.7%CVE-2020-10269CRITICALRVD#2566: Hardcoded Credentials on MiRX00 wireless Access PointEPSS 1.4%CVE-2020-10280HIGHRVD#2568: Apache server is vulnerable to a DoSEPSS 1.2%CVE-2020-10279CRITICALRVD#2569: Insecure operating system defaults in MiR robotsEPSS 1.0%