CVE-2020-7360highCWE-427

CVE-2020-7360: fallo de gravedad alta en Philips SmartControl

Philips SmartControl DLL Hijacking

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 7.4epss 0.5%
An Uncontrolled Search Path Element (CWE-427) vulnerability in SmartControl version 4.3.15 and versions released before April 15, 2020 may allow an authenticated user to escalate privileges by placing a specially crafted DLL file in the search path. This issue was fixed in version 1.0.7, which was released after April 15, 2020. (Note, the version numbering system changed significantly between version 4.3.15 and version 1.0.7.)
CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:L
Productos afectados
Philips · SmartControl