CVE-2021-33538highCWE-269

CVE-2021-33538: fallo de gravedad alta en Weidmüller IE-WL(T)-BL-AP-CL-XX

WEIDMUELLER: WLAN devices affected by improper access control vulnerability

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 8.8epss 1.0%
In Weidmueller Industrial WLAN devices in multiple versions an exploitable improper access control vulnerability exists in the iw_webs account settings functionality. A specially crafted user name entry can cause the overwrite of an existing user account password, resulting in remote shell access to the device as that user. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H