CVE-2022-1669mediumCWE-121

CVE-2022-1669: fallo de gravedad media en CIRCUTOR COMPACT DC-S BASIC

Circutor COMPACT DC-S BASIC

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

13Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 6.8epss 0.8%
A buffer overflow vulnerability has been detected in the firewall function of the device management web portal. The device runs a CGI binary (index.cgi) to offer a management web application. Once authenticated with valid credentials in this web portal, a potential attacker could submit any "Address" value and it would be copied to a second variable with a "strcpy" vulnerable function without checking its length. Because of this, it is possible to send a long address value to overflow the process stack, controlling the function return address.
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H