CVE-2022-36063highCWE-121CWE-191

CVE-2022-36063: fallo de gravedad alta en azure-rtos usbx

USBX Host CDC ECM integer underflow with buffer overflow

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 7.6epss 2.2%
Azure RTOS USBx is a USB host, device, and on-the-go (OTG) embedded stack, fully integrated with Azure RTOS ThreadX and available for all Azure RTOS ThreadX–supported processors. Azure RTOS USBX implementation of host support for USB CDC ECM includes an integer underflow and a buffer overflow in the `_ux_host_class_cdc_ecm_mac_address_get` function which may be potentially exploited to achieve remote code execution or denial of service. Setting mac address string descriptor length to a `0` or `1` allows an attacker to introduce an integer underflow followed (string_length) by a buffer overflow of the `cdc_ecm -> ux_host_class_cdc_ecm_node_id` array. This may allow one to redirect the code execution flow or introduce a denial of service. The fix has been included in USBX release [6.1.12](https://github.com/azure-rtos/usbx/releases/tag/v6.1.12_rel). Improved mac address string descriptor length validation to check for unexpectedly small values may be used as a workaround.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H
Productos afectados
azure-rtos · usbx