CVE-2023-32735
CVE-2023-32735
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Productos afectados
Siemens · SIMATIC STEP 7 Safety V16Siemens · SIMATIC STEP 7 Safety V17Siemens · SIMATIC STEP 7 Safety V18Siemens · SIMATIC STEP 7 V16Siemens · SIMATIC STEP 7 V17Siemens · SIMATIC STEP 7 V18Siemens · SIMATIC WinCC Unified V16Siemens · SIMATIC WinCC Unified V17Siemens · SIMATIC WinCC Unified V18Siemens · SIMATIC WinCC V16Siemens · SIMATIC WinCC V17Siemens · SIMATIC WinCC V18Siemens · SIMOCODE ES V16Siemens · SIMOCODE ES V17Siemens · SIMOCODE ES V18Siemens · SIMOTION SCOUT TIA V5.4 SP1Siemens · SIMOTION SCOUT TIA V5.4 SP3Siemens · SIMOTION SCOUT TIA V5.5 SP1Siemens · SINAMICS Startdrive V16Siemens · SINAMICS Startdrive V17Siemens · SINAMICS Startdrive V18Siemens · SIRIUS Safety ES V17Siemens · SIRIUS Safety ES V18Siemens · SIRIUS Soft Starter ES V17Siemens · SIRIUS Soft Starter ES V18Siemens · Soft Starter ES V16Siemens · TIA Portal Cloud V3.0¿Quieres saber si tu infraestructura está expuesta a esto?
Hablar con TrueHacking →