CVE-2024-0439highCWE-269

CVE-2024-0439: fallo de gravedad alta en mintplex-labs/anything-llm

User can manually send request at manager permission to modify system configurations

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 7.1epss 0.6%
As a manager, you should not be able to modify a series of settings. In the UI this is indeed hidden as a convenience for the role since most managers would not be savvy enough to modify these settings. They can use their token to still modify those settings though through a standard HTTP request While this is not a critical vulnerability, it does indeed need to be patched to enforce the expected permission level.
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:N