CVE-2024-2851mediumexplotación observadaCWE-78

CVE-2024-2851: fallo de gravedad media en Tenda AC15

Tenda AC15 setsambacfg formSetSambaConf os command injection

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

35Vexday Risk Score

Prioriza la corrección. Ella explotación observada por VulnCheck.

ssvc Attendcvss 6.3epss 4.0%
de la publicación al arma
Publicada en NVD24 mar
VulnCheck+899d
A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Productos afectados
Tenda · AC15