Privilege Escalation in MEAC300
The standard user uses the run as function to start the MEAC applications with administrative privileges. To ensure that the system can startup on its own, the credentials of the administrator were stored. Consequently, the EPC2 user can execute any command with administrative privileges. This allows a privilege escalation to the administrative level.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Productos afectados
SICK AG · SICK MEAC300¿Quieres saber si tu infraestructura está expuesta a esto?
Hablar con TrueHacking →Referencias
https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDFhttps://sick.com/psirthttps://www.cisa.gov/resources-tools/resources/ics-recommended-practiceshttps://www.first.org/cvss/calculator/3.1https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0001.jsonhttps://www.sick.com/.well-known/csaf/white/2025/sca-2025-0001.pdf