← volver
CVE-2025-27026mediumCWE-1220

Improper Access Control Granularity impacting Infinera G42

13Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 4.9epss 0.3%
probabilidad de explotación
0.3%top 73% de las CVE
explotación observada
noninguna fuente lo reporta
A missing double-check feature in the WebGUI for CLI deactivation in Infinera G42 version R6.1.3 allows an authenticated administrator to make other management interfaces unavailable via local and network interfaces. The CLI deactivation via the WebGUI does not only stop CLI interface but deactivates also Linux Shell, WebGUI and Physical Serial Console access. No confirmation is asked at deactivation time. Loosing access to these services device administrators are at risk of completely loosing device control.
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
Productos afectados
Infinera · G42