CVE-2025-69426criticalCWE-732CWE-798

CVE-2025-69426: fallo crítico en RUCKUS Networks vRIoT IOT Controller

Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

28Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 10epss 0.4%
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H