CVE-2026-127102highCWE-200CWE-863

CVE-2026-127102: fallo de gravedad alta en Eclipse BaSyx Go Components

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 7.1epss 0.3%
In Eclipse BaSyx Go Components versions up to and including 1.1.2, ABAC-enabled deployments of the Submodel Repository and the AAS Environment return Submodel Elements that the caller is not authorized to read from `GET /submodels/{submodelIdentifier}/submodel-elements`. If an access rule grants READ on a single Submodel Element through a `$sme` `REFERABLE` object, the list route returns every element of that Submodel, including its value, as soon as one element matches the caller's rules. The single-element route and the full Submodel read enforce the same rule and deny access to the other elements. An authenticated caller with a READ grant for one element of a Submodel can therefore read all other elements of that Submodel. The issue is fixed in Eclipse BaSyx Go Components v1.1.3.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N