CVE-2026-12806highCWE-119CWE-120

CVE-2026-12806: fallo de gravedad alta en Edimax BR-6478AC V2

Edimax BR-6478AC V2 POST Request formWlSiteSurvey buffer overflow

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

41Vexday Risk Score

Sin señal de explotación. Ella tiene prueba de concepto pública.

ssvc Attendcvss 8.7epss 0.8%
A vulnerability has been found in Edimax BR-6478AC V2 1.23. The impacted element is the function formWlSiteSurvey of the file /goform/formWlSiteSurvey of the component POST Request Handler. The manipulation of the argument selSSID leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Productos afectados
Edimax · BR-6478AC V2
⚠ Recursos públicos, para evaluar la exposición de sistemas que controlas o estás autorizado a probar. Prueba solo con autorización.