CVE-2026-133851: fallo de gravedad media en flowintel
FlowIntel Alerting: Missing Private Case Authorization Check Allows Connector Owners to Access Revoked Case Data
Publicada el
Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.
10Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackcvss 5.3
FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case.
This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case.
Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case.
Impact:
- Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints.
- Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access.
- Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races.
Affected versions: FlowIntel prior to 4.1.0.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N
Productos afectados
flowintel · flowintelCVEs relacionadas — flowintel
En el mismo producto, de las más peligrosas a las menos.
CVE-2026-133620MEDIUMFlowintel Template Repository Path Traversal and Symlink Escape Allows Arbitrary File ReadEPSS 0.6%CVE-2026-81753MEDIUMFlowintel Stored XSS in Case Notes via Malicious Mermaid Diagram ContentEPSS 0.5%CVE-2026-81662HIGHFlowintel Alert Settings Configuration Allows Remote Code Execution via Arbitrary Configuration KeysEPSS 0.5%CVE-2026-133627MEDIUMflowintel Case History Log Injection via Line Separator Characters in User-Authored FieldsEPSS 0.5%CVE-2026-69075MEDIUMStored Cross-Site Scripting via Vue Template Injection in FlowIntelEPSS 0.5%CVE-2026-81819MEDIUMFlowintel Missing Authorization Allows Regular API Users to View Other Users’ Task AssignmentsEPSS 0.5%