CVE-2026-31495: fallo en Linux
netfilter: ctnetlink: use netlink policy range checks
Publicada el · Actualizada el
Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.
3Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackepss 0.1%
In the Linux kernel, the following vulnerability has been resolved:
netfilter: ctnetlink: use netlink policy range checks
Replace manual range and mask validations with netlink policy
annotations in ctnetlink code paths, so that the netlink core rejects
invalid values early and can generate extack errors.
- CTA_PROTOINFO_TCP_STATE: reject values > TCP_CONNTRACK_SYN_SENT2 at
policy level, removing the manual >= TCP_CONNTRACK_MAX check.
- CTA_PROTOINFO_TCP_WSCALE_ORIGINAL/REPLY: reject values > TCP_MAX_WSCALE
(14). The normal TCP option parsing path already clamps to this value,
but the ctnetlink path accepted 0-255, causing undefined behavior when
used as a u32 shift count.
- CTA_FILTER_ORIG_FLAGS/REPLY_FLAGS: use NLA_POLICY_MASK with
CTA_FILTER_F_ALL, removing the manual mask checks.
- CTA_EXPECT_FLAGS: use NLA_POLICY_MASK with NF_CT_EXPECT_MASK, adding
a new mask define grouping all valid expect flags.
Extracted from a broader nf-next patch by Florian Westphal, scoped to
ctnetlink for the fixes tree.
Productos afectados
Linux · LinuxCVEs relacionadas — Linux
En el mismo producto, de las más peligrosas a las menos.
CVE-2026-31431HIGHcrypto: algif_aead - Revert to operating out-of-placeEPSS 98.1%KEVCVE-2026-46300HIGHnet: skbuff: preserve shared-frag marker during coalescingEPSS 17.2%KEVCVE-2024-53197HIGHALSA: usb-audio: Fix potential out-of-bound accesses for Extigy and Mbox devicesEPSS 4.1%KEVCVE-2024-53104HIGHmedia: uvcvideo: Skip parsing frames of type UVC_VS_UNDEFINED in uvc_parse_formatEPSS 3.4%KEVCVE-2025-39682CRITICALtls: fix handling of zero-length records on the rx_listEPSS 3.3%KEVCVE-2024-36971HIGHnet: fix __dst_negative_advice() raceEPSS 2.7%KEV
Referencias
https://cert-portal.siemens.com/productcert/html/ssa-019113.htmlhttps://cert-portal.siemens.com/productcert/html/ssa-082556.htmlhttps://cert-portal.siemens.com/productcert/html/ssa-457936.htmlhttps://git.kernel.org/stable/c/2ef71307c86a9f866d6e28f1a0c06e2e9d794474https://git.kernel.org/stable/c/435b576cd2faa75154777868f8cbb73bf71644d3https://git.kernel.org/stable/c/45c33e79ae705b7af97e3117672b6cd258dd0b1bhttps://git.kernel.org/stable/c/4f7d25f3f0786402ba48ff7d13b6241d77d975f5https://git.kernel.org/stable/c/675c913b940488a84effdeeac5a1cfb657b59804https://git.kernel.org/stable/c/8f15b5071b4548b0aafc03b366eb45c9c6566704https://git.kernel.org/stable/c/c6cb41eaae875501eaaa487b8db6539feb092292https://git.kernel.org/stable/c/fcec5ce2d73a41668b24e3f18c803541602a59f6