CVE-2026-4638: fallo de gravedad alta en Paessler GmbH PRTG Network Monitor
Plaintext Password Disclosure via VBScript Sensor Error Message in Paessler PRTG Network Monitor
Publicada el
Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.
21Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackcvss 7.1epss 0.3%
PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.
Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
Productos afectados
Paessler GmbH · PRTG Network MonitorCVEs relacionadas — Paessler GmbH PRTG Network Monitor
En el mismo producto, de las más peligrosas a las menos.