Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application
21Vexday Risk Score
Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.
ssvc Trackcvss 7.8epss 0.1%
probabilidad de explotación
0.1%top 97% de las CVE
explotación observada
noninguna fuente lo reporta
It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.
If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Productos afectados
OMRON SOCIAL SOLUTIONS CO., Ltd. · PowerAttendant Standard Edition