CVE-2026-55473mediumCWE-918

CVE-2026-55473: fallo de gravedad media en sysadminsmedia homebox

HomeBox: Notifier SSRF guard misses NAT64 prefixes (64:ff9b::/96, 64:ff9b:1::/48) — generic:// URL reaches cloud metadata on NAT64 egress

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

13Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 6epss 0.4%
HomeBox is a home inventory and organization system. Prior to 0.26.0, the default-on BlockBogonNets and BlockCloudMetadata notifier SSRF protections in backend/internal/sys/validate/notifier_url.go do not inspect IPv4 destinations embedded in the NAT64 prefixes 64:ff9b::/96 and 64:ff9b:1::/48. An authenticated user can submit a generic:// notifier through POST /v1/notifiers or POST /v1/notifiers/test, and on a Homebox instance that egresses through NAT64/DNS64, the gateway can translate an accepted IPv6 destination to cloud metadata, localhost, or another internal IPv4 host. The notifier test path returns delivery result information, and Shoutrrr propagates the response, providing feedback that can disclose retrieved metadata such as temporary credentials. Without NAT64 egress, the crafted IPv6 destination is not routable, but the guard still incorrectly classifies it as safe. This issue is fixed in version 0.26.0.
CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
Productos afectados
sysadminsmedia · homebox