CVE-2026-72895highCWE-1394

CVE-2026-72895: fallo de gravedad alta en Siemens SIMATIC IPC BX-21A

Publicada el · Actualizada el

Aviso por correo cuando entre en el KEV, tenga PoC pública o suba de nota.

21Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 8.4epss 0.1%
A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N