CVE-2026-87674highCWE-78

CVE-2026-87674: fallo de gravedad alta en Brocade Fabric OS

Publicada el

18Vexday Risk Score

Sin señal de explotación. Ningún artefacto público de explotación conocido hasta ahora.

ssvc Trackcvss 8.5
probabilidad de explotación
—
explotación observada
noninguna fuente lo reporta
A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Productos afectados
Brocade · Fabric OS