CVE-2018-0270CWE-352

CVE-2018-0270: falha em Cisco IoT Field Network Director

Publicada em · Atualizada em

Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.

3Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackepss 0.7%
A vulnerability in the web-based management interface of Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated, remote attacker to conduct a cross-site request forgery (CSRF) attack and alter the data of existing users and groups on an affected device. The vulnerability is due to insufficient CSRF protections for the web-based management interface on an affected device. An attacker could exploit this vulnerability by persuading a user of the interface to follow a malicious link. A successful exploit could allow the attacker to perform arbitrary actions with the privilege level of the affected user. If the user has administrative privileges, the attacker could create a new, privileged account to obtain full control over the device interface. This vulnerability affects Connected Grid Network Management System, if running a software release prior to IoT-FND Release 3.0; and IoT Field Network Director, if running a software release prior to IoT-FND Release 4.1.1-6 or 4.2.0-123. Cisco Bug IDs: CSCvi02448.