CVE-2020-10269: falha crítica em Mobile Industrial Robots A/S MiR100
RVD#2566: Hardcoded Credentials on MiRX00 wireless Access Point
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
28Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 9.8epss 1.4%
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Produtos afetados
Mobile Industrial Robots A/S · MiR100CVEs relacionadas — Mobile Industrial Robots A/S MiR100
No mesmo produto, das mais perigosas para as menos.
CVE-2020-10272CRITICALRVD#2554: MiR ROS computational graph presents no authentication mechanismsEPSS 2.5%CVE-2020-10271CRITICALRVD#2555: MiR ROS computational graph is exposed to all network interfaces, including poorly secured wireless networks and open wired onesEPSS 1.8%CVE-2020-10270CRITICALRVD#2557: Hardcoded Credentials on MiRX00 Control DashboardEPSS 1.7%CVE-2020-10276CRITICALRVD#2558: Default credentials on SICK PLC allows disabling safety featuresEPSS 1.5%CVE-2020-10280HIGHRVD#2568: Apache server is vulnerable to a DoSEPSS 1.2%CVE-2020-10279CRITICALRVD#2569: Insecure operating system defaults in MiR robotsEPSS 1.0%