CVE-2021-25667: falha de média gravidade em Siemens RUGGEDCOM RM1224
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
13Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 6.5epss 0.9%
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Produtos afetados
Siemens · RUGGEDCOM RM1224Siemens · SCALANCE M-800Siemens · SCALANCE S615Siemens · SCALANCE SC-600 FamilySiemens · SCALANCE XB-200Siemens · SCALANCE XC-200Siemens · SCALANCE XF-200BASiemens · SCALANCE XM400Siemens · SCALANCE XP-200Siemens · SCALANCE XR-300WGSiemens · SCALANCE XR500CVEs relacionadas — Siemens RUGGEDCOM RM1224
No mesmo produto, das mais perigosas para as menos.