CVE-2023-39457: falha crítica em Triangle MicroWorks SCADA Data Gateway
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
28Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 9.8epss 2.0%
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Produtos afetados
Triangle MicroWorks · SCADA Data GatewayCVEs relacionadas — Triangle MicroWorks SCADA Data Gateway
No mesmo produto, das mais perigosas para as menos.
CVE-2023-39460HIGHTriangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation VulnerabilityEPSS 3.4%CVE-2022-0369HIGHTriangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution VulnerabilityEPSS 2.3%CVE-2023-39464HIGHTriangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution VulnerabilityEPSS 2.0%CVE-2023-39468HIGHTriangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution VulnerabilityEPSS 1.9%CVE-2014-2342—Triangle MicroWorks SCADA Data Gateway Resource ExhaustionEPSS 1.8%CVE-2023-39462MEDIUMTriangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload VulnerabilityEPSS 1.5%