CVE-2024-13894: falha de média gravidade em Smartwares CIP-37210AT
Path traversal in Smartwares cameras
Publicada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
13Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 5.9epss 0.2%
Smartwares cameras CIP-37210AT and C724IP, as well as others which share the same firmware in versions up to 3.3.0, are vulnerable to path traversal.
When an affected device is connected to a mobile app, it opens a port 10000 enabling a user to download pictures shot at specific moments by providing paths to the files. However, the directories to which a user has access are not limited, allowing for path traversal attacks and downloading sensitive information.
The vendor has not replied to reports, so the patching status remains unknown. Newer firmware versions might be vulnerable as well.
CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N