CVE-2024-54005mediumCWE-611

CVE-2024-54005: falha de média gravidade em Siemens COMOS V10.3

Publicada em

Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.

13Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 5.9epss 0.2%
A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.
CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N