CVE-2024-5633: falha de alta gravidade em Longse Technology LBH30FE200W
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 7.5epss 0.6%
Longse model LBH30FE200W cameras, as well as products based on this device, provide an unrestricted access for an attacker located in the same local network to an undocumented binary service CoolView on one of the ports.
An attacker with a knowledge of the available commands is able to perform read/write operations on the device's memory, which might result in e.g. bypassing telnet login and obtaining full access to the device.
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVEs relacionadas — Longse Technology LBH30FE200W
No mesmo produto, das mais perigosas para as menos.