CVE-2025-52961: falha de alta gravidade em Juniper Networks Junos OS Evolved
Junos OS Evolved: PTX Series except PTX10003: An unauthenticated adjacent attacker sending specific valid traffic can cause a memory leak in cfmman leading to FPC crash and restart
Publicada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 7.1epss 0.5%
An Uncontrolled Resource Consumption vulnerability in the Connectivity Fault Management (CFM) daemon and the Connectivity Fault Management Manager (cfmman) of Juniper Networks Junos OS Evolved on PTX10001-36MR, PTX10002-36QDD, PTX10004, PTX10008, PTX10016 allows an unauthenticated, adjacent attacker to cause a Denial-of-Service (DoS).
An attacker on an adjacent device sending specific valid traffic can cause cfmd to spike the CPU to 100% and cfmman's memory to leak, eventually to cause the FPC crash and restart.
Continued receipt and processes of these specific valid packets will sustain the Denial of Service (DoS) condition.
An indicator of compromise is to watch for an increase in cfmman memory rising over time by issuing the following command and evaluating the RSS number. If the RSS is growing into GBs then consider restarting the device to temporarily clear memory.
user@device> show system processes node fpc<num> detail | match cfmman
Example:
show system processes node fpc0 detail | match cfmman
F S UID PID PPID PGID SID C PRI NI ADDR SZ WCHAN RSS PSR STIME TTY TIME CMD
4 S root 15204 1 15204 15204 0 80 0 - 90802 - 113652 4 Sep25 ? 00:15:28 /usr/bin/cfmman -p /var/pfe -o -c /usr/conf/cfmman-cfg-active.xml
This issue affects Junos OS Evolved on PTX10001-36MR, PTX10002-36QDD, PTX10004, PTX10008, PTX10016:
* from 23.2R1-EVO before 23.2R2-S4-EVO,
* from 23.4 before 23.4R2-S4-EVO,
* from 24.2 before 24.2R2-EVO,
* from 24.4 before 24.4R1-S2-EVO, 24.4R2-EVO.
This issue does not affect Junos OS Evolved on PTX10001-36MR, PTX10002-36QDD, PTX10004, PTX10008, PTX10016 before 23.2R1-EVO.
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:L/AU:Y/R:A/V:C/RE:M/U:Green
Produtos afetados
Juniper Networks · Junos OS EvolvedCVEs relacionadas — Juniper Networks Junos OS Evolved
No mesmo produto, das mais perigosas para as menos.
CVE-2026-21902CRITICALJunos OS Evolved: PTX Series: A vulnerability allows a unauthenticated, network-based attacker to execute code as rootEPSS 18.5%CVE-2026-101967CRITICALJunos OS Evolved: PTX Series: An attacker controlled DHCP response causes root-level compromise when zero-touch provisioning is usedEPSS 3.9%CVE-2026-101978HIGHJunos OS Evolved: PTX Series: An attacker controlled gRPC response causes root-level compromise when zero-touch provisioning is usedEPSS 3.9%CVE-2026-102059HIGHJunos OS and Junos OS Evolved: EX Series, SRX Series, QFX Series: A rogue DHCP server causes root-level command execution when the phone-home client processes specific informationEPSS 3.9%CVE-2026-102031CRITICALJunos OS Evolved: A low-privileged TACACS+ user causes root command execution when authorization refresh is enabledEPSS 2.1%CVE-2023-28983HIGHJunos OS Evolved: Shell Injection vulnerability in the gNOI serverEPSS 1.5%