CVE-2026-113709: falha crítica em argoproj argo-cd
Argo CD: A Kustomize Helm config home can run commands in the repo-server
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
28Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 9.9epss 0.5%
Argo CD is a declarative, GitOps continuous delivery tool for Kubernetes. From 2.1.0 until 3.3.15, 3.4.10, 3.5.4, and 3.6.0-rc2, when an operator has enabled --enable-helm for kustomize build, helmGlobals.configHome can point Helm's config and data directories at a repository-controlled location. Helm automatically loads a downloader plugin from `<configHome>/.data/plugins` without a separate plugin-install step and executes its program inside argocd-repo-server when a helmCharts repository URL uses the plugin's protocol. The command runs as the repo-server user and can read repository credentials and other process-accessible data. An attacker can commit the Kustomization and plugin to a Git repository that an Application builds or upload the files through POST /api/v1/applications/manifestsWithFiles, also exposed by argocd app diff --local --server-side-generate. The upload path requires only Application get permission on an existing Application, without Application update or sync permission or repository write access. Both delivery paths require prior operator enablement of --enable-helm; deployments that do not enable it are not affected. Kustomize 4.1.0 first passed helmGlobals.configHome through to Helm. This issue is fixed in versions 3.3.15, 3.4.10, 3.5.4, and 3.6.0-rc2.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Produtos afetados
argoproj · argo-cdCVEs relacionadas — argoproj argo-cd
No mesmo produto, das mais perigosas para as menos.
CVE-2025-59538HIGHArgo CD is Vulnerable to Unauthenticated Remote DoS via malformed Azure DevOps git.push webhookEPSS 9.4%CVE-2025-55190CRITICALArgo CD: Project API Token Exposes Repository CredentialsEPSS 5.7%CVE-2024-37152MEDIUMUnauthenticated Access to sensitive settings in Argo CDEPSS 2.3%CVE-2022-29165CRITICALArgo CD will blindly trust JWT claims if anonymous access is enabledEPSS 2.1%CVE-2026-55797HIGHArgo CD repo-server command injection via crafted SSH repository SOCKS5 proxy URLEPSS 1.9%CVE-2024-31989CRITICALArgoCD Vulnerable to Use of Risky or Missing Cryptographic Algorithms in Redis CacheEPSS 1.5%
Referências
https://argo-cd.readthedocs.io/en/stable/user-guide/kustomize/#kustomizing-helm-chartshttps://github.com/argoproj/argo-cd/commit/b6d5c23bce2f8a46c52975ba438a3b93d242d96chttps://github.com/argoproj/argo-cd/pull/6059https://github.com/argoproj/argo-cd/releases/tag/v3.3.15https://github.com/argoproj/argo-cd/releases/tag/v3.4.10https://github.com/argoproj/argo-cd/releases/tag/v3.5.4https://github.com/argoproj/argo-cd/releases/tag/v3.6.0-rc2https://github.com/argoproj/argo-cd/security/advisories/GHSA-fw5c-w8rc-j7fxhttps://github.com/argoproj/argo-cd/security/advisories/GHSA-j6cw-g6p4-7hchhttps://github.com/kubernetes-sigs/kustomize/pull/3784