CVE-2026-11404highCWE-125

CVE-2026-11404: falha de alta gravidade em Cesanta Mongoose

Cesanta Mongoose Out-of-Bounds Read in MG_TLS_BUILTIN ClientHello Session ID Parsing

Publicada em · Atualizada em

Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.

21Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 8.7epss 0.8%
Cesanta Mongoose before 7.22 contains an out-of-bounds read in the built-in TLS server function mg_tls_server_recv_hello(), which uses an attacker-controlled session_id_len byte from a TLS ClientHello as a buffer index without validating it against the length of received data. A remote, unauthenticated attacker can send a single crafted ClientHello with an oversized session id length to read past the receive buffer, crashing any HTTPS, MQTTS, or WSS service built on MG_TLS_BUILTIN.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Produtos afetados
Cesanta · Mongoose