CVE-2026-120997: falha de baixa gravidade em nerves-hub nerves_hub_web
Improper session invalidation keeps removed or demoted members' open pages and device consoles working at their old role
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
8Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 2.3epss 0.3%
Improper Session Invalidation vulnerability in the dashboard pages, device console and local shell channels in nerves-hub nerves_hub_web allows an organization member who is removed or given a lower role to keep acting at their old role through anything they had open at the time. The dashboard reads the member's role once when a page mounts, in the assign_org_to_scope hook of NervesHubWeb.Auth, and the console, local shell and device event stream channels check membership once at join. Removing a member or changing their role tells none of them, so open pages keep carrying out actions and open consoles keep running commands on the device until the page reloads or the socket disconnects.
The dashboard also opens consoles over NervesHubWeb.UserSocket with a token that holds only the user's id, is accepted for 24 hours, and is not revoked by signing out, which disconnects only the session's LiveViews. Whoever holds a token taken from a page can open consoles as that user, within the user's current membership, until it expires.
This issue affects nerves_hub: from 1.0.0 before 2.5.3.
CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:L/SA:N
Produtos afetados
nerves-hub · nerves_hub_webCVEs relacionadas — nerves-hub nerves_hub_web
No mesmo produto, das mais perigosas para as menos.
CVE-2026-119446CRITICALSession fixation in the CLI login flow allows an unauthenticated attacker to obtain a user's API tokenEPSS 0.5%CVE-2025-64097CRITICALNervesHub has Insufficient Token Entropy that Allows Authentication Bypass via Brute ForceEPSS 0.5%CVE-2026-28806CRITICALImproper authorization in device bulk actions and device update API allows cross-organization device controlEPSS 0.5%CVE-2026-120730HIGHMass assignment of organization, product and deployment group IDs allows users to write into other organizations and receive their firmwareEPSS 0.4%CVE-2026-120295HIGHIncorrect authorization in the devices page bulk move allows view-role members to move devices into another organization and receive its firmwareEPSS 0.2%CVE-2026-120286MEDIUMMissing authorization in device and deployment group page events allows view-role members to change devices and deployment groupsEPSS 0.2%
Referências
https://cna.erlef.org/cves/CVE-2026-120997.htmlhttps://github.com/nerves-hub/nerves_hub_web/commit/a96497ddd4d24ab1847f7685e255bf96fd87b85bhttps://github.com/nerves-hub/nerves_hub_web/commit/b5d2438677f79d10e91aeef20a7b5cd8cca0d63chttps://github.com/nerves-hub/nerves_hub_web/security/advisories/GHSA-c7jf-qcx9-xxf8https://osv.dev/vulnerability/EEF-CVE-2026-120997