CVE-2026-3868: falha de alta gravidade em Moxa EDR-8010 Series
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 8.7epss 0.4%
An improper handling of the length parameter inconsistency vulnerability has been identified in Moxa’s Secure Router. Because of improper validation of length parameters in the HTTPS management interface, an unauthenticated remote attacker could send specially crafted requests that trigger a buffer overflow condition, causing the web service to become unresponsive. Successful exploitation may result in a denial-of-service condition requiring a device reboot to restore normal operation. While successful exploitation can severely impact the availability of the affected device, no impact to the confidentiality or integrity of the affected product has been identified. Additionally, no confidentiality, integrity, or availability impact to the subsequent system has been identified.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
CVEs relacionadas — Moxa EDR-8010 Series
No mesmo produto, das mais perigosas para as menos.
CVE-2024-9140CRITICALCVE-2024-9140EPSS 1.8%CVE-2024-9139HIGHOS Command Injection in Restricted CommandEPSS 1.4%CVE-2023-33239HIGHSecond Order Command-injection Vulnerability in the Key-generation FunctionEPSS 1.3%CVE-2024-9138HIGHPrivilege Escalation in Cellular Router, Secure Router, and Network Security AppliancesEPSS 1.1%CVE-2025-0676HIGHCommend Injection Leading to Privilege EscalationEPSS 1.0%CVE-2023-33238HIGHCommand-injection Vulnerability in Certificate ManagementEPSS 0.8%