CVE-2026-61517: falha de alta gravidade em Netis Systems NX10
Netis NX10 OS Command Injection via Ping Diagnostic Handler
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
41Vexday Risk Score
Sem sinal de exploração. Ela tem prova de conceito pública.
ssvc Attendcvss 8.6epss 2.5%
Netis NX10 firmware V4.0.1.5808 and V3.0.0.4142 contain an OS command injection vulnerability in the ping diagnostic handler that allows authenticated administrators to execute arbitrary shell commands as root by injecting into the IpAddr parameter. The parameter is interpolated directly into a shell command executed through system() with an incomplete denylist that only blocks spaces, pipes, semicolons, and ampersands, leaving command substitution and alternate field separator expansion available for exploitation.
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Produtos afetados
Netis Systems · NX10PoCs públicas encontradas — 1
cve_referencehackwithmike.com/research/netis/2026-09não verificado⚠ Recursos públicos, para você avaliar a exposição de sistemas que controla ou está autorizado a testar. Teste apenas com autorização.
CVEs relacionadas — Netis Systems NX10
No mesmo produto, das mais perigosas para as menos.