CVE-2026-63201: falha de alta gravidade em CESNET netopeer2
netopeer2-server logging has format string vulnerability via subtree filter
Publicada em · Atualizada em
Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.
21Vexday Risk Score
Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.
ssvc Trackcvss 7.1epss 0.4%
Netopeer2 is a server for implementing network configuration management based on the `NETCONF` Protocol. In affected versions, a low-privileged authenticated `NETCONF` user can remotely crash `netopeer2-server` by sending a `get RPC` with an invalid `subtree filter` whose text contains format specifiers. In `src/netconf.c`, `np2srv_rpc_get_cb()` sends the invalid value through `ERR()` to `np2log_printf()`, where `vsnprintf()` first formats the message safely. In `src/log.c`, that already formatted buffer is subsequently passed to `np2log()` as the format string itself, causing `vsyslog()` to interpret attacker-controlled percent sequences and read invalid pointer arguments. The reported denial of service was confirmed on version 2.8.7 using `NETCONF`-over-SSH and AddressSanitizer; reliable remote code execution was not confirmed. `The advisory identifies 2.8.8 as patched`; repository comparisons verify the fix in public release 2.8.21. The affected/fixed boundary remains unresolved because no public 2.8.8 tag was located, which does not establish the status of an untagged 2.8.8 build.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Produtos afetados
CESNET · netopeer2