CVE-2026-9509highCWE-248

CVE-2026-9509: falha de alta gravidade em Suprema BioStar 2 (server)

Uncaught exception vulnerability in Suprema's BioStar

Publicada em

Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.

21Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 8.7epss 0.4%
An unhandled exception in Suprema BioStar 2 (Server), versions 2.9.8, 2.9.10, and 2.9.11, that allows an unauthenticated remote attacker to cause a denial of service (DoS) by sending HTTP POST requests to the ‘/api/migration’ endpoint. This request triggers a failure that halts critical processes, leaving the system offline until the services or server are manually restarted. As a result, access control readers cease to function, and potential failures may occur in third-party integrations. Since the exploit requires no privileges or user interaction and is trivial to automate, the impact on availability is high, and the effect extends to interconnected systems.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
CVEs relacionadas — Suprema BioStar 2 (server)

No mesmo produto, das mais perigosas para as menos.