CVE-2026-95109highCWE-125CWE-787

CVE-2026-95109: falha de alta gravidade em Eclipse ThreadX

Cortex-A7 module data validation checks only the first address of a caller-supplied range

Publicada em

Aviso por e-mail quando ela entrar no KEV, ganhar PoC pública ou subir de nota.

21Vexday Risk Score

Sem sinal de exploração. Nenhum artefato público de exploração conhecido até agora.

ssvc Trackcvss 8.5epss 0.1%
The Cortex-A7 MMU Modules port validates a caller-supplied buffer by translating **one address** — the first byte. The common Module Manager hands its range check the module instance, the start address and the complete byte size; the Cortex-A7 implementation discarded the instance and the size and asked the MMU a single question about the start. A memory-protected module therefore passed any range whose first byte was user-readable, however far the rest of it reached. Privileged dispatch code then read or wrote the whole range. Because every protected-module dispatcher that consumes a buffer or an extra-parameter array goes through this one macro, the defect is not in any individual service: it is in the primitive all of them rely on.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N