CVE-2013-5021
Published · Updated
E-mail alert when it lands in KEV, gets a public PoC or its score goes up.
3Vexday Risk Score
No sign of exploitation. No public exploitation artifact known so far.
ssvc Trackepss 2.1%
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
Affected products
n/a · n/aReferences
http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocumenthttp://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocumenthttp://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdfhttp://zerodayinitiative.com/advisories/ZDI-13-120/