CVE-2019-5617: critical vulnerability in Computing For Good Basic Laboratory…
C4G BLIS Improper Access Control
Published · Updated
E-mail alert when it lands in KEV, gets a public PoC or its score goes up.
28Vexday Risk Score
No sign of exploitation. No public exploitation artifact known so far.
ssvc Trackcvss 10epss 1.3%
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Affected products
Computing For Good · Basic Laboratory Information SystemRelated CVEs — Computing For Good Basic Laboratory…
In the same product, most dangerous first.