← back
CVE-2020-1684highCWE-400

Junos OS: SRX Series: High CPU load due to processing for HTTP traffic when Application Identification is enabled.

21Vexday Risk Score

No sign of exploitation. No public exploitation artifact known so far.

ssvc Trackcvss 7.5epss 1.1%
exploitation probability
1.1%top 37% of all CVEs
observed exploitation
nono source reports it
On Juniper Networks SRX Series configured with application identification inspection enabled, receipt of specific HTTP traffic can cause high CPU load utilization, which could lead to traffic interruption. Application identification is enabled by default and is automatically turned on when Intrusion Detection and Prevention (IDP), AppFW, AppQoS, or AppTrack is configured. Thus, this issue might occur when IDP, AppFW, AppQoS, or AppTrack is configured. This issue affects Juniper Networks Junos OS on SRX Series: 12.3X48 versions prior to 12.3X48-D105; 15.1X49 versions prior to 15.1X49-D221, 15.1X49-D230; 17.4 versions prior to 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S2; 18.4 versions prior to 18.4R2-S5, 18.4R3-S1; 19.1 versions prior to 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R3; 19.4 versions prior to 19.4R2.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H