CVE-2023-2637: high-severity vulnerability in Rockwell Automation FactoryTalk System Services
Rockwell Automation FactoryTalk System Services Vulnerable To Use Of Hard-Coded Cryptographic Key
Published · Updated
E-mail alert when it lands in KEV, gets a public PoC or its score goes up.
21Vexday Risk Score
No sign of exploitation. No public exploitation artifact known so far.
ssvc Trackcvss 7.3epss 0.2%
Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies. Hard-coded cryptographic key may lead to privilege escalation. This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited.
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:H
Affected products
Rockwell Automation · FactoryTalk System ServicesRelated CVEs — Rockwell Automation FactoryTalk System Services
In the same product, most dangerous first.