SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for remote code execution
21Vexday Risk Score
No sign of exploitation. No public exploitation artifact known so far.
ssvc Trackcvss 8.8epss 1.1%
exploitation probability
1.1%top 38% of all CVEs
observed exploitation
nono source reports it
Due to missing input validation during one step of the firmware update process, the product
is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker
can execute arbitrary system commands in the root user’s contexts.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Affected products
SICK AG · SICK InspectorP61xSICK AG · SICK InspectorP62xSICK AG · TDC-X401GLSICK AG · TiM3xxReferences
https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDFhttps://sick.com/psirthttps://www.cisa.gov/resources-tools/resources/ics-recommended-practiceshttps://www.first.org/cvss/calculator/3.1https://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.jsonhttps://www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.pdf